  1 miniature waterproof shielded connectors lf series features 1. ease of shielded termination and connector assembly all components are self-aligning and do not require complex assembly tooling. the shield of the cable is connected with the metal housing of the connector using simple shielding clamp, supplied with the connector. 2. water and dust protected ip68 protection rating. complete protection against dust penetration and against water penetration when mated assembly is submerged at the depth of 1.8 meter for 48 hours. 3. bayonet lock short turn bayonet lock assures secure vibration resistant mating of the connectors. 4. acquired safety standard 4 pos. is 10a and meets safety standards (t?v) also 3- and 4-pos. have acquired the ul standard. 5. high current rating capacity 2011.5 mating: insert the plug, and then turn the locking collar clockwise, as indicated by the coupling direction marking. plug locking collar receptacle un-mating: turn the locking collar counter-clockwise than pull off the plug. coupling direction marking coupling direction marking 2 1 1 2 36.4 receptacle plug ?13 8.9 mm max. (3 pos.) mated dimensions (example : lf07) short turn bayonet lock built-in shield connection spring cable shielding connection clamp cable shielding connection - plug number of contacts 3 4 6, 12 and 20 11 current rating 5a max. 10a max. 2a max. 10a max. 2a max. the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
2 lf series miniature waterproof shielded connectors 1a dc frequency: 10 to 55hz, single amplitude of 0.75mm, acceleration of 98 m/s 2 for 3 hours in 3 axis. acceleration of 490m/s 2 , 11ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis. 1000 cycles temperature: -55? ? room temperature ? +125? ? room temperature time: 30 ? 2 to 3 ? 30 ? 2 to 3 (minutes) 5 cycles 96 hours at temperature of 40? and humidity of 90% to 95%. complete dust protection. no water penetration when submerged for 48 hours at the depth of 1.8 meter. no electrical discontinuity for 10s max. no electrical discontinuity for 10s max. insulation resistance: 100 m? min. insulation resistance: 1 10 m? min. (when temperature high) insulation resistance: 100 m? min. (dray state) when mated with corresponding connector. 1000 m? min. 30 m? max. (3, 6, 12, 20 pos.) 10 m? max. (4 pos.) 10 m? max.(a to d), 30 m? max.(1 to 7)(11pos.) 500v dc (3, 4 pos.) 100v dc (6, 12, 20 pos.) 500v dc (a to d), 100v dc (1 to 7)(11pos.) no flashover or insulation breakdown. 1250v ac/one minute (3, 4 pos.) 300v ac/one minute (6, 12, 20 pos.) 1250v ac(a to d),300v ac(1 to 7) / one minute(11pos.) 1 1.contact resistance 1 2.insulation resistance 1 3.withstanding voltage 1 4.vibration 1 5.shock 1 6.durability 16. (mating/un-mating) 1 7.temperature cycle 1 8.humidity 1 9.water / dust protection 15 m? max. (3, 6, 12, 20 pos.) 1 5 m? max. (4 pos.) 1 5 m? max. (a to d), 15m? max. (1 to 7)(11 pos.) rating voltage rating current rating operating temperature range storage temperature range C 25? to +85? (note 1) C 10? to +60? (note 2) 125v ac, 175v dc (3 pos.) 125v ac, 125v dc (4 pos.) 30v ac, 42v dc (6 pos. , 12pos. , 20pos.) 125v ac, dc (11 pos. a to d) 30v ac, 42v dc (11 pos. 1 to 7) 5a max. (3 pos.) 10a max. (4 pos.) 2a max. (6 pos. , 12pos. , 20pos.) 10a(11 pos. a to d), 2a(11 pos. 1 to 7) product specifications item specification conditions material finish / color remarks CCCCCCCCCC ul94v-0 CCCCCCCCCC CCCCCCCCCC body / back shell insulator contacts gasket zinc alloy pps copper alloy chloroprene rubber nickel plated black gold plated black materials / finish note 1: includes temperature rise caused by the current flow. note 2: the term ?torage?refers to products stored for long period of time prior to mounting and use. operating temperature r ange and humidity range covers non-conducting condition of installed connectors in storage, shipment or during transportation. please determine the specific product. if listed needed, please select and order the product no. ordering information series name : lf shell size 07 10 13 waterproof w : waterproof type lock mechanism b : bayonet lock connector type p : plug r : receptacle j : jack ( *:form change zoning symbols in an identical class ) number of contacts : 3, 4, 6, 11, 12, 20 contact type p : male contact s : female contact -- s 6 p b w 07 lf * * 1 2 3 4 5 6 7 1 2 3 4 5 6 7 components the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
3 lf series miniature waterproof shielded connectors plugs ?a b ?c (cable dia.) ?a b ?c(cable dia.) plugs lock ease type unit:mm (shown one example) unit:mm part number cl no. contact number of contacts ?a ?b ?c c weight lf10wbpd-4s lf10wbpd-4p lf10wbpd-12s lf10wbpd-12p 136-0014-3-00 136-0017-1-00 136-0015-6-00 136-0018-4-00 male female male female 4 12 16.8 41.8 7.3 19g part number cl no. contact number of contacts ?a b ?c weight lf07wbp-3s lf07wbp-3p lf07wbp-6s lf07wbp-6p lf10wbp-4s LF10WBP-4P lf10wbp-12s lf10wbp-12p lf13wbp-20s lf13wbp-20p lf13wbp-11s lf13wbp-11p 136-0003-7 136-0004-0 136-0001-1 136-0002-4 136-0005-2 136-0006-5 136-0007-8 136-0008-0 136-0009-3 136-0010-2 136-0011-5 136-0012-8 female male female male female male female male female male female male 3 6 4 12 20 11 12.3 14.8 17.9 35.8 41.8 51.9 5 7.3 8.7 11g 17g 29g the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
4 lf series miniature waterproof shielded connectors note: recommended hex nut tightening torque: 1.5 to 2 nm (3,4,6, and 12 pos.), 2 to 2.5 nm (11, 20 pos.) e ?a ?b c d f(hex) receptacles unit:mm part number cl no. contact number of contacts ?a ?b ?c c d e weight lf07wbr-3p lf07wbr-3s lf07wbr-6p lf07wbr-6s lf10wbr-4p lf10wbr-4s lf10wbr-12p lf10wbr-12s lf13wbr-20p lf13wbr-20s lf13wbr-11p lf13wbr-11s 136-1003-2 136-1004-5 136-1001-7 136-1002-0 136-1005-8 136-1006-0 136-1007-3 136-1008-6 136-1009-9 136-1010-8 136-1011-0 136-1012-3 male female male female male female male female male female male female 3 6 4 12 20 11 10.3 12.8 15.9 13 15.3 18.3 7.75 16.55 15.05 15.25 19.05 17.25 17.25 19.05 7.65 7.75 1 m90.75 m110.75 m140.75 4g 6g 5g 6g 9g 10g 9g 10g f 11 13 17 ?a c e d ?b receptacles rear panel mount type ?solder type unit:mm part number cl no. contact number of contacts ?a ?b ?c c d e weight lf10wbrb-4p lf10wbrb-12p lf10wbrb-12s 136-1118-4-00 136-1013-6-00 136-1014-9-00 male male female 4 12 12.8 18.3 19.05 17.25 17 m140.75 10g the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
5 lf series miniature waterproof shielded connectors ?a c e d ?b rear panel mount type ?through hole type unit:mm part number cl no. contact number of contacts ?a ?b ?c c d e weight lf10wbrb-12pd lf10wbrb-12sd 136-1015-1-00 136-1016-4-00 male female 12 12.8 18.3 17.5 17 m140.75 10g jacks ?a ?b c ?d ( cable dia. ) part number cl no. contact number of contacts ?a ?b c ?d weight lf07wbj-3p lf07wbj-3s lf07wbj-6p lf07wbj-6s lf10wbj-4p lf10wbj-4s lf10wbj-12p lf10wbj-12s lf13wbj-20p lf13wbj-20s lf13wbj-11p lf13wbj-11s 136-2003-8 136-2004-0 136-2001-2 136-2002-5 136-2005-3 136-2006-6 136-2007-9 136-2008-1 136-2009-4 136-2010-3 136-2011-6 136-2012-9 male female male female male female male female male female male female 3 6 4 12 20 11 10.3 12.8 15.9 11.5 13.8 16.9 36.3 42.4 52.4 5 .0 7.3 8.7 11g 16g 29g 30g 29g 30g unit:mm (shown one example) the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
6 lf series miniature waterproof shielded connectors cap for receptacles b ?a part number cl no. applicable connector ?a b weight lf10wbr-c lf13wbr-c 136-3001-8-00 136-3003-3-00 lf10ebr-4p lf10wbr-4s lf10wbr-12p lf10wbr-12s lf10wbrb-4p lf10wbrb-12p lf10wbrb-12s lf10wbrb-12pd lf10wbrb-12sd lf13wbr-20p lf13wbr-20s lf13wbr-11p lf13wbr-11s 14.8 17.9 8.8 8.75 5g 7g unit:mm the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
7 lf series miniature waterproof shielded connectors applicable tools solder termination fixture contact configuration shell size lf07 lf10 lf13 number of contacts withstanding voltage current rating insulation resistance contact resistance solder pot inner diameter 3 1250v ac 5a 1000m? 15m? 1.15mm 6 300v ac 2a 0.8mm a +0.05 0 alignment guide b +0.05 0 panel cutout contact position arrangement and specifications 1 3 2 1 2 3 4 5 6 note 1: the contact configuration as viewed from the female contact connector mating side. note 2: the symbol indicates polarizing key position. note 3: withstanding voltages are test voltage values. part number description cl no. lf series applicable cable dia. hr10a-tc-02 lf-tc-01 manual cable clamp crimp note: applicable cable dia. is only 5mm for lf series. 150-0041-2 150-0234-6 5 (note) 7.3 8.7 cl no. part number applicable connectors 150-0232-0 150-0233-3 150-0235-9 150-0236-1 150-0237-4 150-0238-7 lf07bp-t01 lf07bj-t01 lf10bp-t01 lf10bj-t01 lf13bp-t01 lf13bj-t01 lf07wbp-6s,6p,3s,3p lf07wbj-6s,6p,3s,3p lf10wbp-4s,4p,12s,12p lf10wbj-4s,4p,12s,12p lf13wbp-20s,20p,11s,11p lf13wbj-20s,20p,11s,11p shell size a b panel thickness unit (mm) lf07wbr- lf10wbr- lf13 wbr- lf10wbrb- ?9.05 ?11.05 ?14.05 ?14.05 8.1 10.2 13.1 13.1 0.7 to 2 0.7 to 2 0.7 to 2 0.7 to 2 4 1250v ac 10a 1000m? 5m? 1.7mm 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 a b 2 5 6 1 3 7 4 d c 3 2 1 8 7 6 9 10 4 5 17 16 20 13 12 11 14 15 18 19 12 300v ac 2a 1000m? 15m? 0.8mm 11 20 ac300v 2a 1000m? 4m? 0.8mm unit:mm 4 ? 1.7 4 5m? 7 ? 0.8 7 15m? 1000m? 7 2a 7 ac300v 4 ac1250v 4 10a (shown one example) (shown one example) the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
8 lf series miniature waterproof shielded connectors termination and assembly instructions no. illustration operation solder termination fixture 1 plug 1 plug disassembly insertion direction body / insulator assembly locking collar backshell 2 1 2 1 2 1 2 solder termination fixture jack insertion direction body / insulator assembly backshell jack disassembly insert the plug into securely held solder termination fixture as shown. loosen the backshell turning it counter clockwise and remove it from the body/ insulator assembly. insert the jack into the securely held solder termination fixture as shown. loosen the backshell turning it counterclockwise. notes 1 2 connector assembly (1) (2) (3) backshell threaded section tightening collar threaded section 1 apply a coating of loctite 7649 (manufactured by henckel japan, ltd,) primer to the threaded sections of the backshell and the tightening collar. completely dry the coated surfaces. drying time at room temperature is approximately 30 to 70 seconds. ensure sufficient ventilation of the area at time of drying. take necessary steps to protect the coated surfaces from contamination. fixture part no. applicable connector lf07bp-t01 lf07wbp-6s,6p,3s,3p lf10bp-t01 lf13bp-t01 lf10wbp-4s,4p,12s,12p lf13wbp-20s,20p,11s,11p fixture part no. applicable connector lf07bj-t01 lf07wbj-6s,6p,3s,3p lf10bj-t01 lf13bj-t01 lf10wbj-4s,4p,12s,12p lf13wbj-20s,20p,11s,11p the connectors are delivered with pre-assembed condition and the disassembly as shown no.1. the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
9 lf series miniature waterproof shielded connectors 3 2 2 cable preparation cable outer jacket shielding mesh a 1 tightening collar strain relief collar backshell no. 1 seal bushing cable cable preparation end 2 shielding mesh (folded back) wires cable outer jacket 2 4 to 5mm 2 3 3 table 2. stripping dimensions cable outer jacket wires shielding mesh cable outer jacket b conductors wires stripping dimensions thread the tightening collar, strain relief collar, seal bushing and the backshell over the cable as illustrated. strip the cables outer jacket to the dimensions illustrated in the table 1. fold back the shielding mesh over the cables outer jacket assuring that it is uniform on its diameter. strip the wires to the dimensions illustrated in the table 2. notes (1) (2) exercise caution not to damage the shielding mesh. any damage to the cables outer jacket may affect the waterproof performance of the assembled connector. notes threading the components may not be possible after the cable-end finishing process notes when stripping the wires exercise caution not to damage its insulation, folded over shielding mesh or cables outer jacket. it may cause deffects in insulation, conduction, and waterproof performance. illustration operation table 1. stripping dimensions number of conductors a mm 3 6 8 to 9 4 13 to 14 12 11 20 14 to 15 23 to 24 23 to 24 (no.1 to 7) 22 to 23 (no.a to d) 20.5 30.5 20.5 number of conductors b mm 3 6 2.50.5 4 12 11 20 20.5 20.5 (no.1 to 7) 30.5 (no.a to d) stripping dimensions the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
10 lf series miniature waterproof shielded connectors no. 4 soldering 1 insulator contact wire cmm heat-shrink tubing C 1 2 3 2 C 2 3, 4, 11 /p"?%
conductors 2 3 insulator insulator wall insulator 0.5 mm min. wire insulation C 2 wire insulation shielding mesh (folded back) insulator wall contact contact solder % cable outer jacket after the soldering, keep a distance of % between the contact end and the cables outer jacket as illustrated. soldering conditions soldering iron tip temperature: 35010? soldering time: within 5 sec. notes (1) (2) assure that the solder compound is sufficiently melted on the soldering iron tip. when applying, make sure that the solder will flow correctly at all the contact surfaces between the conductor and the contact. 2 C 1 6, 12, 20, 11 /p?
conductors (1) (2) (3) place a heat-shrink tubing (inside diameter of 1.1 mm min.) over every other wire. perform the soldering of the contact and the conductor, with the wires insulation touching the contact as shown. after soldering, slide the heat shrink tubing over the soldered joint and shrink it. the tubing should touch the insulator as shown. (1) (2) perform the soldering of the contact and the conductor, with the wires insulation touching the contact as illustrated. when soldering, to maintain the insulation between adjacent contacts. make sure that the wires insulation remains below the edge of the insulators wall 0.5 mm min., as illustrated. note the distance of % is required in order to assure correct assembly of the backshell. illustration operation number of conductors 3 6 % mm 6 to 7 4 18 to 19 12 10 to 11 13 to 14 11 20 table 4. wire dimensions $ mm          up up up up up up up up   table 3 heat shrink tubing dimensions number of conductors number of contacts the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
11 lf series miniature waterproof shielded connectors no. 2 1 3 soldered joints cable outer jacket cable outer jacket 5 to 6mm cable outer jacket shielding mesh wires copper tape 2 mm max. 3 copper tape copper tape wires copper tape overlap of the copper tape crimping of the shielding clamp solder termination fixture body / insulator assembly 2 1 10.5mm cable outer jacket ground clamp shielding clamp shielding mesh 5 4 commercially available pliers 4 overlap of the copper tape e shielding clamp after completion of the soldering operations carefully remove (holding on the locking collar) the body/insulator assembly from the solder termination fixture. wrap the folded over shielding mesh with 5 to 6 mm wide copper tape to assure that it will not become loose. apply the copper tape so that the shielding mesh does not protrude from under it. insert the u shaped shielding clamp over the copper tape as shown on the illustration. it is critical that the overlap of the copper tape is located inside the shielding clamp as shown on the illustration. using commercially available pliers bend the open ends of the shielding clamp as illustrated, assuring that it stays in place. the dimension of e. between opposing edges of the shielding clamp is necessary to assure correct final crimp. note exercise caution not to damage or deform the solder joints. note after wrapping the copper tape, the tape should overlap itself by 2 mm max. illustration operation note when the end of the copper tape wrapping is positioned at the open side of the ground fitting, the end portion of the copper tape wrapping will no longer be covered by the ground fitting when the ground fitting is crimped. table 5 shell size & -' -' nnnby nnnby -' the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
12 lf series miniature waterproof shielded connectors no. 5 6 5 5 note it is critical that the cable itself will not turn or twist during this operation. it may cause breakage at the soldered area. note it is critical that the protrusions are inside the corresponding grooves. it may cause breakage, when a tightening collar is assembled. forming cavity crimping tool 5.3 7.0 connector assembly 12 , backshell threaded section wrench width : d 3 4 5 5 34 , tightening collar groove protrusion strain relief collar seal bushing tightening collar threaded section both sides of the shielding clamp must be placed in the forming cavity of the tool (as shown on the illustration) and crimped over the cable by closing the tool completely. 1 place the body/insulator assembly in the applicable solder termination fixture. slide forward the seal bushing and insert it in the backshell until fully seated. verify that the locktite 7649 primer (or equivalent) on the threaded sections of the backshell and tightening collar are dry. apply the locktite 271 compound to the tightening collars threaded section and attach it to the backshell. slide forward the strain relief collar and insert it in the backshell, making sure that the opposing protrusions fit inside the corresponding grooves, as shown on the illustration. 2 coat the thread section of the body/insulator assembly with loctite 271 compound (manufactured by henckel japan, ltd.) or equivalent, tightening it with a torque specified in the table 6. illustration operation crimping tool forming cavity applicable cable diameter shielding clamp diameter after crimping hr10a-tc-02 5.3 5mm CCC 7.3mm 8.7mm 5.3mm to 5.5mm CCC 7.9mm to 8.1mm 9.1mm to 9.3mm 7.0 lf-tc-01 7.9 9.1 shell size tightening torque wrench width lf07 lf10 10mm 1n m~1.5n m 1n m~1.5n m 13mm lf13 1.5n m~2n m 16mm table 6 (recommend tightening torgue) fixture part no. applicable connector fixture part no. applicable connector lf07bp-t01 lf10bp-t01 lf13bp-t01 lf07wbp-6s,6p,3s,3p lf10wbp-4s,4p,12s,12p lf13wbp-20s,20p,11s,11p lf07bj-t01 lf10bj-t01 lf13bj-t01 lf07wbj-6s,6p,3s,3p lf10wbj-4s,4p,12s,12p lf13wbj-20s,20p,11s,11p for plug assembly for jack assembly the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
13 lf series miniature waterproof shielded connectors no. 6 6 6 remove the connector from the solder termination fixture, holding it by the locking collar. do not pull on the cable. it may cause breakage. tightening collar illustration operation shell size tightening torque wrench width lf07 lf10 lf13 10mm 0.8n m~1n m 0.7n m~1n m 1 n m~1.5 n m 13mm 16mm wrench width recommended tightening torgue 1. to maintain the water/dust protection performance and the cable clamp force, use a cable that is within the range of applica ble diameter. 2. consult hrs representative when using different cables. conductor insulator shield jacket cable specifications (reference) no. of contact 3 pos. 20 pos. soft copper wire ?0.16 7 /?0.16 mm dia. awg #26 0.14 ?0.48 ?0.9 (standard) 0.21 soft copper wire 80% ?5.1 ?8.70.2 material size (mm) construction size (awg) sectional area diameter (mm) diameter (mm) thickness (mm) material density diameter (mm) diameter (mm) soft copper wire ?0.18 20 /?0.18 mm dia. awg #20 0.5 ?0.98 ?1.5 (standard) 0.26 soft copper wire 85% ?3.6 ?50.2 4 pos. 11 pos. soft copper wire ?0.16 7 /?0.16 mm dia. awg #26 0.14 ?0.48 ?0.95 (standard) 0.24 6 pos. soft copper wire ?0.16 7 /?0.16 mm dia. awg #26 0.14 ?0.48 ?0.88 (standard) 0.2 soft copper wire 85% ?3.4 ?50.2 12 pos. soft copper wire ?0.16 7 /?0.16 mm dia. awg #26 0.14 ?0.48 ?0.9 (standard) 0.21 soft copper wire 80% ?4.2 ?7.30.2 soft copper wire ?0.26 20 /?0.26 mm dia. awg #16 1.25 ?1.5 ?2.1 (standard) 0.3 soft copper wire 80% ?5.5 ?7.30.2 soft copper wire ?0.26 26 /?0.26 mm dia. awg #16 1.25 ?1.5 ?2.1 (standard) 0.3 80% ?6.7 ?8.70.2 soft copper wire the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
14 lf series miniature waterproof shielded connectors notes : the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
15 lf series miniature waterproof shielded connectors notes : the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.
16 lf series miniature waterproof shielded connectors usa: hirose electric (u.s.a.), inc. headquarters 2688 westhills court, simi valley, ca 93065-6235 phone : 1-805-522-7958 fax : 1-805-522-3217 http://www.hiroseusa.com hong kong: hirose electric hongkong trading co., ltd. room 1001, west wing, tsim sha tsui centre, 66 mody road, tsim sha tsui east, kowloon, hong kong phone : 852-2803-5338 fax : 852-2591-6560 http://www.hirose-hongkong.com.hk china: hirose electric (shanghai) co., ltd. beijing branch a1001, ocean international center, building 56# east 4th ring middle road, chao yang district, beijing, 100025 phone : 86-10-5165-9332 fax : 86-10-5908-1381 http://www.hirose-china.com.cn taiwan: hirose electric taiwan co., ltd. 103 8f, no.87, zhengzhou rd., taipei phone : 886-2-2555-7377 fax : 886-2-2555-7350 http://www.hirose-taiwan.com.tw germany: hirose electric europe b.v. german branch herzog-carl-strasse 4 d-73760 ostfildern (scharnhauser park) phone : 49-711-4560-02-1 fax : 49-711-4560-02-299 http://www.hirose.de singapore: hirose electric singapore pte. ltd. 10 anson road #26-16 international plaza 079903 phone : 65-6324-6113 fax : 65-6324-6123 http://www.hirose-singapore.com.sg the netherlands: hirose electric europe b.v. hogehillweg #8 1101 cc amsterdam z-o phone : 31-20-6557460 fax : 31-20-6557469 http://www.hiroseeurope.com uk: hirose electric europe b.v. uk branch first floor, st andrews house, caldecotte lake business park, milton keynes mk7 8le phone : 44-1908-369060 fax : 44-1908-369078 http://www.hirose.co.uk usa: hirose electric (u.s.a.), inc. detroit office (automotive) 37677 professional center drive, suite #100c livonia, mi 48154 phone : 1-734-542-9963 fax : 1-734-542-9964 http://www.hiroseusa.com usa: hirose electric (u.s.a.), inc. north california office 20400 stevens creek blvd., ste 250, cupertino, ca 95014 phone : 1-408-253-9640 fax : 1-408-253-9641 http://www.hiroseusa.com china: hirose electric (shanghai) co., ltd. 1601,henderson metropolitan,no.300 ,east nanjing road,huangpu district, shanghai,china 200001 phone : 86-21-6391-3355 fax : 86-21-6391-3335 http://www.hirose-china.com.cn china: hirose electric technologies (shenzhen) co., ltd. room 09-13, 19/f, office tower shun hing square, di wang commercial centre 5002, shennandong road, shenzhen city, guangdong province, 518008 phone : 86-755-8207-0851 fax : 86-755-8207-0873 http://www.hirose-china.com.cn korea: hirose korea co., ltd. 1261-10, jeoungwhang-dong, shihung-city, kyunggi-do 429-450 phone : 82-31-496-7000,7124 fax : 82-31-496-7100 http://www.hirose.co.kr the contents of this catalog are current as of date of 05/2011. contents are subject to change without notice for the purpose o f improvements. 5-23,osaki 5-chome,shinagawa-ku,tokyo 141-8587,japan phone: 81-3-3491-5300, fax: 81-3-3495-5230 http://www.hirose.com http://www.hirose-connectors.com the product information in this catalog is for reference only. please request the engineering drawing for the most current and accurate design information.


▲Up To Search▲   

 
Price & Availability of LF10WBP-4P

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X